Multi fuel flexible liner made from 904L grade stainless
steel on the inner and 316L grade stainless steel on the outer walls, both the
smooth inner liner and convoluted outer skin being 0.12mm thick. - 15 year
manufacturers warranty with this product.
Wednesday, 19 March 2014
Flue Liner 10 inch Rain Cap

Provides rain protection at the top of the stack.
Provides rain protection at the top of the stack.
APPLICATION
Provides rain protection at the top of the stack.
Provides rain protection at the top of the stack.
INSTALLATION
Terminal slides over the top of the liner and can be screwed into place with self tapping screws (not supplied) or alternatively can be cemented in to place at the top of the stack.
MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.
Terminal slides over the top of the liner and can be screwed into place with self tapping screws (not supplied) or alternatively can be cemented in to place at the top of the stack.
MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.
Friday, 14 March 2014
Flue Liner 316L for Gas and Oil (316L Grade)

APPLICATION
A single skin flexible flue liner suitable for relining within a masonry chimney. Suitable for use on appliances fired by gas ( as specified by the fire manufacturer ), and oils up to 28 second, and designed to accommodate temperatures not exceeding 260ËšC.
A single skin flexible flue liner suitable for relining within a masonry chimney. Suitable for use on appliances fired by gas ( as specified by the fire manufacturer ), and oils up to 28 second, and designed to accommodate temperatures not exceeding 260ËšC.
CONSTRUCTION
The flue liner is manufactured from 316L grade stainless steel and is 0.10mm thick. The flue liner has five convoluteions between each seam. The Flue Liner seam is folded in three planes to give a TRIPLELOCK seal.
The flue liner is manufactured from 316L grade stainless steel and is 0.10mm thick. The flue liner has five convoluteions between each seam. The Flue Liner seam is folded in three planes to give a TRIPLELOCK seal.
APPROVAL
TRIPLELOCK Flue Liner is Kitemarked to BS 715 and has been approved and tested to BS EN 1856:2
TRIPLELOCK Flue Liner is Kitemarked to BS 715 and has been approved and tested to BS EN 1856:2
DESIGNATION
NUMBER
BS EN 1856:2 T250 N1 D V3 L50010 G
BS EN 1856:2 T250 N1 D V3 L50010 G
INSTALLATION
- CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.
INSTALLATION
Flue Liner should always be fitted from the top.
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone. If necessary cut the flue liner to length, and secure the liner at the top using the clamp plate. Ensure 75mm of the flue liner projects above the clamp plate so that the terminal can be located and secured.
Secure and seal the flue liner to a register plate, which closes off the appliance recess. Alternatively the end of the flue liner can be sealed into flue pipe or a Flue Gas Collector or Flue Box.
Terminate the flue liner by securley fitting the terminal to the projecting section of flue liner. Apply a suitable cement as a seal and weather proof render.
MAINTENANCE
It is recommended that chimneys serving gas and oil appliances be swept and maintained as frequently as necessary but at least once a year.
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.
INSTALLATION
Flue Liner should always be fitted from the top.
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone. If necessary cut the flue liner to length, and secure the liner at the top using the clamp plate. Ensure 75mm of the flue liner projects above the clamp plate so that the terminal can be located and secured.
Secure and seal the flue liner to a register plate, which closes off the appliance recess. Alternatively the end of the flue liner can be sealed into flue pipe or a Flue Gas Collector or Flue Box.
Terminate the flue liner by securley fitting the terminal to the projecting section of flue liner. Apply a suitable cement as a seal and weather proof render.
MAINTENANCE
It is recommended that chimneys serving gas and oil appliances be swept and maintained as frequently as necessary but at least once a year.
Monday, 10 March 2014
Flue-Liner Installation Kit 5 - 5 inch

Installation Pack No. 5, ALL YOU NEED IN ONE BOX FOR USE
WITH 125mm diameter multifuel flex.
APPLICATION
Use this pack when you want to remove the existing chimney pot, or the chimney does not have a pot.
Use this pack when you want to remove the existing chimney pot, or the chimney does not have a pot.
PACK
CONTAINS
1 x Top Plate - diam125mm
1 x Top Clamp - diam125mm
1 x Top Insert - diam125mm
1 x Nose Cone - diam125mm
1 x Increasing Adaptor to Black Pipe or Single Wall Flue - diam100mm SW to diam125mm Flex
1 x Chimney Notice Plate
1 x Rain Cap - diam125mm
1 x Top Plate - diam125mm
1 x Top Clamp - diam125mm
1 x Top Insert - diam125mm
1 x Nose Cone - diam125mm
1 x Increasing Adaptor to Black Pipe or Single Wall Flue - diam100mm SW to diam125mm Flex
1 x Chimney Notice Plate
1 x Rain Cap - diam125mm
Thursday, 6 March 2014
7 inch Flue Liner 904L/904L Grade Multifuel (904L/904L Grade)

Multi fuel flexible liner made from 904L grade stainless
steel on both the inner and outer walls - 25 year manufacturers warranty with
this product
APPLICATION
A double skinned flexible flue liner suitable for relining within a masonry chimney. Flue liner is suitable for use with burning gas, oil, coal, coke, cured dry logs, cured dry peat, smokeless fuels.
A double skinned flexible flue liner suitable for relining within a masonry chimney. Flue liner is suitable for use with burning gas, oil, coal, coke, cured dry logs, cured dry peat, smokeless fuels.
CONSTRUCTION
The flue liner has a smooth inner liner made from 904L grade stainless steel and is 0.12mm thick. The flue liner has a convoluted outer skin made from 904L stainless steel and is 0.12mm thick. The Flue Liner is constructed from a single strip of steel which is bent at 180 degrees and then the seam is folded in four planes to give a quattrolock seal.
The flue liner has a smooth inner liner made from 904L grade stainless steel and is 0.12mm thick. The flue liner has a convoluted outer skin made from 904L stainless steel and is 0.12mm thick. The Flue Liner is constructed from a single strip of steel which is bent at 180 degrees and then the seam is folded in four planes to give a quattrolock seal.
APPROVAL
Flue Liner is approved and listed by HETAS
WARRANTY
904L Grade Flue Liner is warranted for 25 years (conditions apply)
Flue Liner is approved and listed by HETAS
WARRANTY
904L Grade Flue Liner is warranted for 25 years (conditions apply)
INSTALLATION
- CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.
INSTALLATION
Flue Liner should always be fitted from the top.
Make sure the arrows are pointing upwards (gas flow).
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.
INSTALLATION
Flue Liner should always be fitted from the top.
Make sure the arrows are pointing upwards (gas flow).
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.
MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.
Wednesday, 5 March 2014
Flue Liner 316L for Gas and Oil (316L Grade) 7 inch

MAINTENANCE
It is recommended that chimneys serving gas and oil appliances be swept and maintained as frequently as necessary but at least once a year.
Suitable for use on appliances fired by gas ( as
specified by the fire manufacturer ), and oils up to 28 second.
APPLICATION
A single skin flexible flue liner suitable for relining within a masonry chimney. Suitable for use on appliances fired by gas ( as specified by the fire manufacturer ), and oils up to 28 second, and designed to accommodate temperatures not exceeding 260°C.
A single skin flexible flue liner suitable for relining within a masonry chimney. Suitable for use on appliances fired by gas ( as specified by the fire manufacturer ), and oils up to 28 second, and designed to accommodate temperatures not exceeding 260°C.
CONSTRUCTION
The flue liner is manufactured from 316L grade stainless steel and is 0.10mm thick. The flue liner has five convolutions between each seam. The Flue Liner seam is folded in three planes to give a TRIPLELOCK seal.
The flue liner is manufactured from 316L grade stainless steel and is 0.10mm thick. The flue liner has five convolutions between each seam. The Flue Liner seam is folded in three planes to give a TRIPLELOCK seal.
APPROVAL
TRIPLELOCK Flue Liner is kite marked to BS 715 and has been approved and tested to BS EN 1856:2
TRIPLELOCK Flue Liner is kite marked to BS 715 and has been approved and tested to BS EN 1856:2
DESIGNATION
NUMBER
BS EN 1856:2 T250 N1 D V3 L50010 G
BS EN 1856:2 T250 N1 D V3 L50010 G
INSTALLATION
- CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.
INSTALLATION
Flue Liner should always be fitted from the top.
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone. If necessary cut the flue liner to length, and secure the liner at the top using the clamp plate. Ensure 75mm of the flue liner projects above the clamp plate so that the terminal can be located and secured.
Secure and seal the flue liner to a register plate, which closes off the appliance recess. Alternatively the end of the flue liner can be sealed into flue pipe or a Flue Gas Collector or Flue Box.
Terminate the flue liner by securley fitting the terminal to the projecting section of flue liner. Apply a suitable cement as a seal and weather proof render.
Flue Liner should always be fitted from the top.
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone. If necessary cut the flue liner to length, and secure the liner at the top using the clamp plate. Ensure 75mm of the flue liner projects above the clamp plate so that the terminal can be located and secured.
Secure and seal the flue liner to a register plate, which closes off the appliance recess. Alternatively the end of the flue liner can be sealed into flue pipe or a Flue Gas Collector or Flue Box.
Terminate the flue liner by securley fitting the terminal to the projecting section of flue liner. Apply a suitable cement as a seal and weather proof render.
MAINTENANCE
It is recommended that chimneys serving gas and oil appliances be swept and maintained as frequently as necessary but at least once a year.
Friday, 28 February 2014
Fireplace Hearth Fence 120x120x120x65cm
Aduro offers a three sided child safety screen.
The robust screen can be placed in front of the oven to secure that small children do not come to close to the flames. The design still ensures a good view of the flames. Measures: Height: 65 cm, Width: 120x120x120 cm Powder coated black metal. |
Subscribe to: