Combustion air vent for heat producing appliances.
Internal baffles reduce light and draughts. Verifiable equivalent area
calculation by Advantica. HETAS approved for use with solid fuel appliances.
Core drilled - suitable for retrofit installations. Grilles U.V. stabilised to
protect against fading. Tube: 127mm Dia. x 358mm L Grilles: 166mm L x 160mm H
Monday, 13 January 2014
Flue Liner 316L/904L Grade Multifuel (316L/904L Grade) - 6 inch

Multi fuel flexible liner made from 904L grade stainless
steel on the inner and 316L grade stainless steel on the outer walls, both the
smooth inner liner and convoluted outer skin being 0.12mm thick. - 15 year
manufacturers warranty with this product.
APPLICATION
A double skinned flexible flue liner suitable for relining within a masonry chimney. Flue liner is suitable for use with burning gas, oil, coal, coke, cured dry logs, cured dry peat, some smokeless fuels.
A double skinned flexible flue liner suitable for relining within a masonry chimney. Flue liner is suitable for use with burning gas, oil, coal, coke, cured dry logs, cured dry peat, some smokeless fuels.
CONSTRUCTION
The flue liner has a smooth inner liner made from 904L grade stainless steel and is 0.12mm thick. The flue liner has a convoluted outer skin made from 316L stainless steel and is 0.12mm thick. The Flue Liner is constructed from two strips of steel and the seam is folded in three planes to give a triplelock seal.
The flue liner has a smooth inner liner made from 904L grade stainless steel and is 0.12mm thick. The flue liner has a convoluted outer skin made from 316L stainless steel and is 0.12mm thick. The Flue Liner is constructed from two strips of steel and the seam is folded in three planes to give a triplelock seal.
APPROVAL
Flue Liner is approved and listed by HETAS
Flue Liner is approved and listed by HETAS
WARRANTY
904L/316L Grade Flue Liner is warranted for 15 years (conditions apply)
904L/316L Grade Flue Liner is warranted for 15 years (conditions apply)
INSTALLATION
- CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.
INSTALLATION
Flue Liner should always be fitted from the top.
Make sure the arrows are pointing upwards (gas flow).
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.
Flue Liner should always be fitted from the top.
Make sure the arrows are pointing upwards (gas flow).
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.
MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.
Wednesday, 8 January 2014
Chimney System Packs - 5 inch House Internal
The Chimney Pack is used when you are running the
flue internally through your house. All the parts you require are included in
the Chimney Pack.
CONTENTS
The pack contains:-
1 x Stove Pipe
1 x DT - Adaptor To Stove Pipe
5 x DT - Pipe 1000mm
1 x DT - Pipe 500mm
1 x DT - Terminal
1 x RES 2 EPDM Flashing
1 x DT - Storm Collar
2 x DT - Floor Support
1 x DT - Roof Support
4 x DT - Ventilated Firestop Plate
7 x DT - Locking Bands
1 x Chimney Notice Plate
1 x Carbon Monoxide Alarm
1 x High Temperature Sealant
The pack contains:-
1 x Stove Pipe
1 x DT - Adaptor To Stove Pipe
5 x DT - Pipe 1000mm
1 x DT - Pipe 500mm
1 x DT - Terminal
1 x RES 2 EPDM Flashing
1 x DT - Storm Collar
2 x DT - Floor Support
1 x DT - Roof Support
4 x DT - Ventilated Firestop Plate
7 x DT - Locking Bands
1 x Chimney Notice Plate
1 x Carbon Monoxide Alarm
1 x High Temperature Sealant
APPLICATION
For use on solid fuel and gas/oil appliances. eg: woodstoves, gas coal effect fires, oil boiler, condensing boilers and any solid fuel appliances.
For use on solid fuel and gas/oil appliances. eg: woodstoves, gas coal effect fires, oil boiler, condensing boilers and any solid fuel appliances.
CONSTRUCTION
Outer skin is made from 304 grade stainless steel and is 0.5mm thick. Inner skin is made from 316 grade stainless steel and is 0.5mm thick. Insulation is compressed rockwool which is injected into the flue giving a density of 180kg per cubic metre. All parts are fully welded – making DT suitable for condensing appliances.
Distance to combustibles is 50mm.
Outer skin is made from 304 grade stainless steel and is 0.5mm thick. Inner skin is made from 316 grade stainless steel and is 0.5mm thick. Insulation is compressed rockwool which is injected into the flue giving a density of 180kg per cubic metre. All parts are fully welded – making DT suitable for condensing appliances.
Distance to combustibles is 50mm.
APPROVALS
DT is HETAS Approved and is CE marked.
Designation Number is
EN1856-1 T600 N1 D V2 L50050 G50.
DT is HETAS Approved and is CE marked.
Designation Number is
EN1856-1 T600 N1 D V2 L50050 G50.
Wednesday, 11 December 2013
MI Rota-Top 200 (Terracotta Top and Base) Bolt Fix

Suitable for chimney sizes 125mm (5 inch) to 250mm (10
inch). Wind driven revolving chimney cowl. Stainless steel construction with
fully cast base. Fully enclosed brass bearings. Can be used on chimneys with
appliances fired by gas, oil or solid fuel. Claw bolt fixing for added security.
Monday, 2 December 2013
Gas Liner 7 inch Nose Cone

The nose cone is attached to the leading end of the
liner, it helps prevent snagging against the side of the stack during
installation. Please note that draw cords are not supplied.
APPLICATION
The nose cone helps prevent snagging of a flue liner against the side of the stack during installation.
The nose cone helps prevent snagging of a flue liner against the side of the stack during installation.
INSTALLATION
Insert a draw cord or string (not supplied) into the hole of the nose cone. Secure with a knot. make sure the draw cord is long enough to reach to the bottom of the stack. Now tape or secure the nose cone to the flue liner end.
Insert a draw cord or string (not supplied) into the hole of the nose cone. Secure with a knot. make sure the draw cord is long enough to reach to the bottom of the stack. Now tape or secure the nose cone to the flue liner end.
MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.
Thursday, 28 November 2013
1mm Stainless Steel 300mm Pipe - 7 inch

APPLICATION
Suitable for gas, oil and solid fuel appliances with temperatures up to 750 degrees C.
1mm Stainless Steel Stove pipe should only be used as a connecting pipe between your appliance and Flue Liner / Chimney Stack / Twin Wall Flue System.
1mm Stainless Steel Stove Pipe should NOT be used to pass through ceilings or wall.
Suitable for gas, oil and solid fuel appliances with temperatures up to 750 degrees C.
1mm Stainless Steel Stove pipe should only be used as a connecting pipe between your appliance and Flue Liner / Chimney Stack / Twin Wall Flue System.
1mm Stainless Steel Stove Pipe should NOT be used to pass through ceilings or wall.
CONSTRUCTION
1mm Stainless Steel Stove Pipe is a single skin flue system manufactured in 316 grade stainless steel and is 1mm thick.
Suitable for gas, oil and solid fuel appliances with temperatures up to 750 degrees C
1mm Stainless Steel Stove Pipe is a single skin flue system manufactured in 316 grade stainless steel and is 1mm thick.
Suitable for gas, oil and solid fuel appliances with temperatures up to 750 degrees C
INSTALLATION
You should not install a piece of 1mm Stainless Steel Stove Pipe within 3 times the diameter of the flue from combustible material, e.g. wood, plaster boards, etc.
A 5 inch (125mm) diameter piece of 1mm Stainless Steel Stove Pipe should be 15 inches (375mm) away from combustible materials.
When installing make sure 1mm Stainless Steel Stove Pipe is installed the correct way up - the smaller convoluted diameter should always be pointing downward.
This is because all the condensates will stay within the flue system and not pass to the outside of Stove Pipe.
Each joint should be coated with a jointing compound (fire cement or high temperature silicone sealant).This makes sure that no condensate can escape and spoil the appearance of the pipe.
Each part should then be secured by using a Joint Clamp Band.
You should not install a piece of 1mm Stainless Steel Stove Pipe within 3 times the diameter of the flue from combustible material, e.g. wood, plaster boards, etc.
A 5 inch (125mm) diameter piece of 1mm Stainless Steel Stove Pipe should be 15 inches (375mm) away from combustible materials.
When installing make sure 1mm Stainless Steel Stove Pipe is installed the correct way up - the smaller convoluted diameter should always be pointing downward.
This is because all the condensates will stay within the flue system and not pass to the outside of Stove Pipe.
Each joint should be coated with a jointing compound (fire cement or high temperature silicone sealant).This makes sure that no condensate can escape and spoil the appearance of the pipe.
Each part should then be secured by using a Joint Clamp Band.
MAINTENANCE
You should make provision for inspecting and cleaning the chimney. This is particularly important on solid fuel applications.
You can acheive this by installing a pipe with an access door.
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.
You should make provision for inspecting and cleaning the chimney. This is particularly important on solid fuel applications.
You can acheive this by installing a pipe with an access door.
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.
Friday, 22 November 2013
5 inch Pellet Pipe - Tee F/F Black enamel finish

90 degree tee with two female ends, one to connect to
the appliance and the other to connect to the next section of pipe. The one male
end is used to connect the Tee Cap (sold seperately). You will need a tee cap
with this item and also TWO gasket seals.
Subscribe to: