Wednesday, 21 August 2013

Quattro-PLUS Flue Liner 904L Grade - Solid Fuel 250mm (10 inch)
** Quattro-PLUS Flue Liner 904L Grade - Solid Fuel 250mm (10 inch)

WARRANTY
904L Grade Flue Liner is warranted for 20 years (conditions apply)

APPLICATION
A double skinned flexible flue liner suitable for relining within a masonry chimney. Flue liner is suitable for use with burning gas, oil, coal, coke, cured dry logs, cured dry peat, smokeless fuels.

CONSTRUCTION
The flue liner has a smooth inner liner made from 904L grade stainless steel and is 0.12mm thick. The flue liner has a convoluted outer skin made from 904L stainless steel and is 0.12mm thick. The Flue Liner is constructed from a single strip of steel which is bent at 180 degrees and then the seam is folded in four planes to give a quattrolock seal.

APPROVAL
Flue Liner is approved and listed by HETAS

INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.


INSTALLATION
Flue Liner should always be fitted from the top.
Make sure the arrows are pointing upwards (gas flow).
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.


MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.

Tuesday, 30 July 2013

Gather Hood 300mm x 300mm Base

 ** Gather Hood 300mm x 300mm Base

Gathers are used on open fires and baskets. The formed stainless steel gather is connected to the multi fuel liner in the chimney. The gather helps the flow of gases up the chimney, it also prevents the liner coming into contact with a fierce heat that can be produced.

Thursday, 25 July 2013

Installation Kit 4 6 inch

** Installation Kit 4 6 inch

Installation Pack No. 4, ALL YOU NEED IN ONE BOX FOR USE WITH 150mm diameter multifuel flex
 
APPLICATION
Use this pack when you want to remove the existing chimney pot - and then replace it when the flue liner is installed. You will probably need to install a cowl or terminal for your chimney to offer some weather and bird protection.

PACK CONTAINS
1 x Top Plate - Ø150mm
1 x Top Clamp - Ø150mm
1 x Top Insert - Ø150mm
1 x Nose Cone - Ø150mm
1 x Increasing Adaptor to Black Pipe or Single Wall Flue - Ø125mm SW to Ø150mm Flex
1 x Chimney Notice Plate

Wednesday, 24 July 2013

Solid Fuel Birdguard (terracotta) - bolt fix

 ** Solid Fuel Birdguard (terracotta) - bolt fix

Designed to prevent animal and debris build up into used (for solid fuel appliances) or unused chimney flues. Fits chimney pots with outside diameters from 230mm-290mm. This product is secured by bolts. Terracotta finish.

Friday, 19 July 2013

Ecofan 812 - AirMax Black and Brass

** Ecofan 812 - AirMax Black and Brass

The 812 Series Ecofan is a heat powered fan designed to circulate the warm air created by a wood-stove operating with normal surface temperatures of between 65°C and 345°C. The optimal running temperature of the wood-stove Ecofan is the same as the recommended safe operating temperature for wood-stoves of between 205°C and 345°C. The Ecofan generates it`s own electricity - so no need for batteries or mains power.

Tuesday, 16 July 2013

Chimney System Pack - House Internal

House Internal

The Chimney Pack is used when you are running the flue internally through your house. All the parts you require are included in the Chimney Pack.
 
CONTENTS
The pack contains:-
1 x Stove Pipe
1 x DT - Adaptor To Stove Pipe
5 x DT - Pipe 1000mm
1 x DT - Pipe 500mm
1 x DT - Terminal
1 x RES 2 EPDM Flashing
1 x DT - Storm Collar
2 x DT - Floor Support
1 x DT - Roof Support
4 x DT - Ventilated Firestop Plate
7 x DT - Locking Bands
1 x Chimney Notice Plate
1 x Carbon Monoxide Alarm
1 x High Temperature Sealant

APPLICATION
For use on solid fuel and gas/oil appliances. eg: woodstoves, gas coal effect fires, oil boiler, condensing boilers and any solid fuel appliances.

CONSTRUCTION
Outer skin is made from 304 grade stainless steel and is 0.5mm thick. Inner skin is made from 316 grade stainless steel and is 0.5mm thick. Insulation is compressed rockwool which is injected into the flue giving a density of 180kg/m³. All parts are fully welded – making DT suitable for condensing appliances.
Distance to combustibles is 50mm.

APPROVALS
DT is HETAS Approved and is CE marked.

Designation Number
EN1856-1 T600 N1 D V2 L50050 G50.

Monday, 15 July 2013

Flue Liner 316L Grade Multifuel (316L/316L Grade)

** Flue Liner 316L Grade Multifuel (316L/316L Grade)

WARRANTY
316L Grade Flue Liner is warranted for 10 years (conditions apply)


APPLICATION
A double skinned flexible flue liner suitable for relining within a masonry chimney. Flue liner is suitable for use with burning gas, oil, coal, coke, cured dry logs, cured dry peat.

CONSTRUCTION
The flue liner has a smooth inner liner made from 316L grade stainless steel and is 0.12mm thick. The flue liner has a convoluted outer skin made from 316L stainless steel and is 0.12mm thick. The Flue Liner is constructed from a single strip of steel which is bent at 180 degrees and then the seam is folded in four planes to give a quattrolock seal.

APPROVAL
Flue Liner is approved and listed by HETAS

INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.


INSTALLATION
Flue Liner should always be fitted from the top.
Make sure the arrows are pointing upwards (gas flow).
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.

MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.