125mm (5 inch) - Installation Kit 1


125mm (5 inch) - Installation Kit 1

Installation Pack No. 1, ALL YOU NEED IN ONE BOX FOR USE WITH 125mm diameter multifuel flex

APPLICATION
Use this pack when you want to remove the existing chimney pot - and then replace it when the flue liner is installed. You will probably need to install a cowl or terminal for your chimney to offer some weather and bird protection.

PACK CONTAINS
1 x Top Plate - Ø125mm
1 x Top Clamp - Ø125mm
1 x Top Insert - Ø125mm
1 x Nose Cone - Ø125mm
1 x Adapter to Black Pipe or Single Wall Flue - Ø125mm
1 x Chimney Notice Plate

125mm (5 inch) - Flue Liner 316L/904L Grade Multifuel (316L/904L Grade)


125mm (5 inch)  -  Flue Liner 316L/904L Grade Multifuel (316L/904L Grade)

WARRANTY
904L/316L Grade Flue Liner is warranted for 10 years (conditions apply)

APPLICATION
A double skinned flexible flue liner suitable for relining within a masonry chimney. Flue liner is suitable for use with burning gas, oil, coal, coke, cured dry logs, cured dry peat, some smokeless fuels.
If the appliance is mainly going to be used to burn wood, and the appliance is not DEFRA approved you should increase the diameter of the Flue Liner to 150mm (providing this will fit in the masonry chimney), as recommended by Building Regulations.

CONSTRUCTION
The flue liner has a smooth inner liner made from 904L grade stainless steel and is 0.12mm thick. The flue liner has a convoluted outer skin made from 316L stainless steel and is 0.12mm thick. The Flue Liner is constructed from two strips of steel and the seam is folded in three planes to give a triplelock seal.

APPROVAL
Flue Liner is approved and listed by HETAS

INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.

INSTALLATION
Flue Liner should always be fitted from the top.
Make sure the arrows are pointing upwards (gas flow).
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.

MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.

125mm (5 inch) - Flue Liner 316L Grade Multifuel (316L/316L Grade)


125mm (5 inch)  -  Flue Liner 316L Grade Multifuel (316L/316L Grade)

WARRANTY
316L Grade Flue Liner is warranted for 10 years (conditions apply)

APPLICATION
A double skinned flexible flue liner suitable for relining within a masonry chimney. Flue liner is suitable for use with burning gas, oil, coal, coke, cured dry logs, cured dry peat.
If the appliance is mainly going to be used to burn wood, and the appliance is not DEFRA approved you should increase the diameter of the Flue Liner to 150mm (providing this will fit in the masonry chimney), as recommended by Building Regulations.

CONSTRUCTION
The flue liner has a smooth inner liner made from 316L grade stainless steel and is 0.12mm thick. The flue liner has a convoluted outer skin made from 316L stainless steel and is 0.12mm thick. The Flue Liner is constructed from a single strip of steel which is bent at 180 degrees and then the seam is folded in four planes to give a quattrolock seal.

APPROVAL
Flue Liner is approved and listed by HETAS

INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.

INSTALLATION
Flue Liner should always be fitted from the top.
Make sure the arrows are pointing upwards (gas flow).
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.

MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.

Vermiculite (100L Bag)


Vermiculite (100L Bag)

The insulating properties of vermiculite significantly reduces the heat loss in cold weather and keeps the interior cool in hot weather. For insulating solid fuel and wood burning liners, it reduces the amount of condensates by keeping the flue warm, it also holds the liner rigid to aid sweeping.

The Honeywell SF450EN Carbon Monoxide Alarm


Honeywell SF450EN Carbon Monoxide Alarm

The SF450EN is an easy to use and reliable self-contained Carbon Monoxide alarm.
Designed for use in all domestic environments such as homes, caravans and boats.
Batteries supplied and pre-fitted in alarm.

IT IS NOW PART OF UK BUILDING REGULATIONS FROM 1st OCTOBER 2010 THAT A (CO) ALARM IS FITTED IN TO A DWELLING WHERE A NEW OR REPLACEMENT FIXED SOLID FUEL APPLIANCE IS INSTALLED.
( Document J ) Building Regs 2010

GUARANTEE
The SF450EN has a 6 Year Guarantee

CONSTRUCTION
SF450EN has a superior electrochemical cell sensing technology
Automatic sensor adjustment function ensures complete accuracy

APPROVAL
SF450EN is approved to EN50291:2001

INSTALLATION
The SF450EN should be installed in the same room as the appliance.
On the ceiling at least 300mm from any wall or, if it is located on a wall, as high as possible (above doors and windows) but not within 150mm of the ceiling AND
between 1m and 3m horizontally from the appliance.

MAINTENANCE
The SF450EN needs no maintenance for the full 6.5 year life of the alarm, with no sensors or any parts to replace.
Batteries supplied and pre-fitted in alarm.

The Chimney Notice Plate


Chimney Notice Plate

Chimney Notice plates are a Building Regulations requirement. They most be filled out and fixed near to the appliance or within a meter cupboard.

The 100mm (4 inch) Joiner


The 100mm (4 inch) Joiner

Allows the joining of two pieces of multi fuel liner (only to be used in none flueing applications)