Tuesday 20 May 2014

Flue Liners - 4 inch DS Flue Liner 316L/904L Grade - Solid Fuel 100mm (4 inch)

** DS Flue Liner 316L/904L Grade - Solid Fuel 100mm (4 inch)

Multi fuel flexible liner made from 904L grade stainless steel on the inner and 316L grade stainless steel on the outer walls, both the smooth inner liner and convoluted outer skin being 0.12mm thick. - 15 year manufacturers warranty with this product.
 
APPLICATION
A double skinned flexible flue liner suitable for relining within a masonry chimney. Flue liner is suitable for use with burning gas, oil, coal, coke, cured dry logs, cured dry peat, some smokeless fuels.
CONSTRUCTION
The flue liner has a smooth inner liner made from 904L grade stainless steel and is 0.12mm thick. The flue liner has a convoluted outer skin made from 316L stainless steel and is 0.12mm thick. The Flue Liner is constructed from two strips of steel and the seam is folded in three planes to give a triplelock seal.
APPROVAL
Flue Liner is approved and listed by HETAS
INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.

 

INSTALLATION
Flue Liner should always be fitted from the top.
Make sure the arrows are pointing upwards (gas flow).
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.
 
MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.

Thursday 15 May 2014

Gas Liner - 6 inch Oil Cowl (Chinamans Hat)

** Oil Cowl (Chinamans Hat)

This type of cowl must be used terminate a liner installed on an oil installation.

APPLICATION
A single skin flexible flue liner suitable for relining within a masonry chimney. Suitable for use on appliances fired by gas ( as specified by the fire manufacturer ), and oils up to 28 second, and designed to accommodate temperatures not exceeding 260ËšC.

CONSTRUCTION
The flue liner is manufactured from 316L grade stainless steel and is 0.10mm thick. The flue liner has five convoluteions between each seam. The Flue Liner seam is folded in three planes to give a TRIPLELOCK seal.

APPROVAL
TRIPLELOCK Flue Liner is Kitemarked to BS 715 and has been approved and tested to BS EN 1856:2

DESIGNATION NUMBER
BS EN 1856:2 T250 N1 D V3 L50010 G

INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.


INSTALLATION
Flue Liner should always be fitted from the top.
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).


Now attach the Nose Cone onto the end of the Flue Liner
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone. If necessary cut the flue liner to length, and secure the liner at the top using the clamp plate. Ensure 75mm of the flue liner projects above the clamp plate so that the terminal can be located and secured.
Secure and seal the flue liner to a register plate, which closes off the appliance recess. Alternatively the end of the flue liner can be sealed into flue pipe or a Flue Gas Collector or Flue Box.
Terminate the flue liner by securley fitting the terminal to the projecting section of flue liner. Apply a suitable cement as a seal and weather proof render.

 


MAINTENANCE
It is recommended that chimneys serving gas and oil appliances be swept and maintained as frequently as necessary but at least once a year.

Wednesday 14 May 2014

Flue Liner 904L/904L Grade Multifuel (904L/904L Grade)

** Flue Liner 904L/904L Grade Multifuel (904L/904L Grade)

Multi fuel flexible liner made from 904L grade stainless steel on both the inner and outer walls - 25 year manufacturers warranty with this product.
 
APPLICATION
A double skinned flexible flue liner suitable for relining within a masonry chimney. Flue liner is suitable for use with burning gas, oil, coal, coke, cured dry logs, cured dry peat, smokeless fuels.
CONSTRUCTION
The flue liner has a smooth inner liner made from 904L grade stainless steel and is 0.12mm thick. The flue liner has a convoluted outer skin made from 904L stainless steel and is 0.12mm thick. The Flue Liner is constructed from a single strip of steel which is bent at 180 degrees and then the seam is folded in four planes to give a Quattro lock seal.
APPROVAL
Flue Liner is approved and listed by HETAS

WARRANTY

904L Grade Flue Liner is warranted for 25 years (conditions apply)
INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.
 
INSTALLATION
Flue Liner should always be fitted from the top.
Make sure the arrows are pointing upwards (gas flow).
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.
MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.

Tuesday 6 May 2014

Gas Liners - 5 inch GC1 Gas Terminal

** GC1 Gas Terminal
Gas terminal (GC1). This type of cowl must be used to terminate a liner installed on gas fired appliances.

APPLICATION
Gas terminal (GC1). This type of cowl must be used to terminate a liner installed on gas fired appliances.

INSTALLATION
Place the terminal over the protruding liner, you can screw a stainless steel screw through the cowl and flue liner to secure. Now apply a suitable acid resistant cement as a seal and weather proof render over the clamp plate and up to the bottom holes of the cowl.
 

MAINTENANCE
It is recommended that chimneys serving gas and oil appliances be swept and maintained as frequently as necessary but at least once a year.

Wednesday 30 April 2014

Gas Liners - Oil Cowl (Chinamans Hat)

** Oil Cowl (Chinamans Hat)

APPLICATION
A single skin flexible flue liner suitable for relining within a masonry chimney. Suitable for use on appliances fired by gas ( as specified by the fire manufacturer ), and oils up to 28 second, and designed to accommodate temperatures not exceeding 260ËšC.

CONSTRUCTION
The flue liner is manufactured from 316L grade stainless steel and is 0.10mm thick. The flue liner has five convoluteions between each seam. The Flue Liner seam is folded in three planes to give a TRIPLELOCK seal.

APPROVAL
TRIPLELOCK Flue Liner is Kitemarked to BS 715 and has been approved and tested to BS EN 1856:2

DESIGNATION NUMBER
BS EN 1856:2 T250 N1 D V3 L50010 G

INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.


INSTALLATION
Flue Liner should always be fitted from the top.
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone. If necessary cut the flue liner to length, and secure the liner at the top using the clamp plate. Ensure 75mm of the flue liner projects above the clamp plate so that the terminal can be located and secured.
Secure and seal the flue liner to a register plate, which closes off the appliance recess. Alternatively the end of the flue liner can be sealed into flue pipe or a Flue Gas Collector or Flue Box.
Terminate the flue liner by securley fitting the terminal to the projecting section of flue liner. Apply a suitable cement as a seal and weather proof render.

 

MAINTENANCE
It is recommended that chimneys serving gas and oil appliances be swept and maintained as frequently as necessary but at least once a year.

Tuesday 22 April 2014

Flue Liner Installation Kit 3 5 inch

** Installation Kit 3 5 inch

Installation Pack No. 3, ALL YOU NEED IN ONE BOX FOR USE WITH 125mm diameter multifuel flex.
 
APPLICATION
Use this pack when you DO NOT want to remove the existing chimney pot.
PACK CONTAINS
1 x Stainless Steel Pot Hanging Cowl with Mesh - diam125mm
1 x Nose Cone - diam125mm
1 x Adaptor to Black Pipe or Single Wall Flue - diam125mm
1 x Chimney Notice Plate

Friday 11 April 2014

Chimney System - 6 inch Premium DT Black - Pipe 1000mm

** DT Black - Pipe 1000mm

1000mm Pipe Length.
The effective installed length is 962mm

APPLICATION
For use on solid fuel and gas/oil appliances. eg: woodstoves, gas coal effect fires, oil boiler, condensing boilers and any solid fuel appliances.

CONSTRUCTION
Outer skin is made from 304 grade stainless steel and is 0.5mm thick. This outer skin is powder coated matt black. Inner skin is made from 316 grade stainless steel and is 0.5mm thick. Insulation is compressed rockwool which is injected into the flue giving a density of 180kgper cubic metre. All parts are fully welded – making DT suitable for condensing appliances.
Distance to combustibles is 50mm.

APPROVALS
DT is HETAS Approved and is CE marked.Designation Number is
EN1856-1 T600 N1 D V2 L50050 G50.

INSTALLATION
DT Twin Wall Insulated Chimney has a simple twist fit joint system, this is then secured by using a Locking Band - the simplest and strongest construction system on the market today.
Make sure that you keep a distance of 50mm from the outside of the flue to any combustible material (wood, plaster board). This distance is only for DT, other flues on the market may have distance of 60mm or more (this is because of the quality of the product) – please ask your supplier.

Tuesday 8 April 2014

Chimney System Black - 135º Tee diam 125 - BLACK

** 135º Tee diam 125 - BLACK

The 135Ëš Tee is used when you need a cleaning access at the base of the chimney. It is the first piece installed on the external wall and allows for ease cleaning of the flue. The 135Ëš Tee is shaped in such away that it does not restrict the flue gases.
This item comes with a 2 FREE Locking Bands.

APPLICATION
For use on solid fuel and gas/oil appliances. eg: woodstoves, gas coal effect fires, oil boiler and any solid fuel appliances.

CONSTRUCTION
Outer skin is made from 304 grade stainless steel and is 0.4mm thick. This is then powder coated in a high temperature Black finish. The Inner skin is made from 316 grade stainless steel and is 0.4mm thick. Insulation is compressed rockwool giving a density of 128kgper cubic metre. All parts are fully welded.
Distance to combustibles is 60mm.

APPROVALS
KC is HETAS Approved and is CE marked.Designation Number is
EN1856-1 T600 N1 D V2 L50040 G60.

INSTALLATION
KC Twin Wall Insulated Chimney parts are secured together by using a Locking Band (supplied).
Make sure that you keep a distance of 60mm from the outside of the flue to any combustible material (wood, plaster board).

Monday 7 April 2014

Cowls - MI Rota-Top 200 (Terracotta Top and Base) Strap Fix
** MI Rota-Top 200 (Terracotta Top and Base) Strap Fix
 
Suitable for chimney sizes 125mm (5 inch) to 250mm (10 inch). Wind driven revolving chimney cowl. Stainless steel construction with fully cast base. Fully enclosed brass bearings. Can be used on chimneys with appliances fired by gas, oil or solid fuel. Claw bolt fixing for added security.

Thursday 3 April 2014

Chimney System - 5 inch Premium DT Black - Pipe 1000mm

** DT Black - Pipe 1000mm

APPLICATION
For use on solid fuel and gas/oil appliances. eg: woodstoves, gas coal effect fires, oil boiler, condensing boilers and any solid fuel appliances.

CONSTRUCTION
Outer skin is made from 304 grade stainless steel and is 0.5mm thick. This outer skin is powder coated matt black. Inner skin is made from 316 grade stainless steel and is 0.5mm thick. Insulation is compressed rockwool which is injected into the flue giving a density of 180kgper cubic metre. All parts are fully welded – making DT suitable for condensing appliances.
Distance to combustibles is 50mm.

APPROVALS
DT is HETAS Approved and is CE marked.
Designation Number is
EN1856-1 T600 N1 D V2 L50050 G50.

INSTALLATION
DT Twin Wall Insulated Chimney has a simple twist fit joint system, this is then secured by using a Locking Band - the simplest and strongest construction system on the market today.
Make sure that you keep a distance of 50mm from the outside of the flue to any combustible material (wood, plaster board). This distance is only for DT, other flues on the market may have distance of 60mm or more (this is because of the quality of the product) – please ask your supplier.

Wednesday 2 April 2014

Cowls - Junior Birdguard (terracotta) - strap fix

** Junior Birdguard (terracotta) - strap fix
Designed to prevent birds, vermin and leaves entering used (for oil or gas appliances) or unused chimney flues. This product provides good ventilation and gives protection against wind and rain. Fits flue sizes 125-250mm internal diameter. This product is secured by a strap fixing. Steel finish.

Friday 28 March 2014

Flue Liners - Flue Liner 316L Grade Multifuel (316L/316L Grade)

** Flue Liner 316L Grade Multifuel (316L/316L Grade)

Multi fuel flexible liner made from 316L grade stainless steel - 10 year manufacturers warranty with this product

APPLICATION
A double skinned flexible flue liner suitable for relining within a masonry chimney. Flue liner is suitable for use with burning gas, oil, coal, coke, cured dry logs, cured dry peat.

CONSTRUCTION
The flue liner has a smooth inner liner made from 316L grade stainless steel and is 0.12mm thick. The flue liner has a convoluted outer skin made from 316L stainless steel and is 0.12mm thick. The Flue Liner is constructed from a single strip of steel which is bent at 180 degrees and then the seam is folded in four planes to give a Quattro lock seal.

APPROVAL
Flue Liner is approved and listed by HETAS

WARRANTY
316L Grade Flue Liner is warranted for 10 years (conditions apply)

INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.


INSTALLATION
Flue Liner should always be fitted from the top.
Make sure the arrows are pointing upwards (gas flow).
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).

Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.

MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.

Tuesday 25 March 2014

Quattro-PLUS Flue Liner 904L Grade - Solid Fuel 250mm (10 inch)

** Quattro-PLUS Flue Liner 904L Grade - Solid Fuel 250mm (10 inch)

Multi fuel flexible liner made from 904L grade stainless steel on both the inner and outer walls - 25 year manufacturers warranty with this product.
 
WARRANTY
904L Grade Flue Liner is warranted for 20 years (conditions apply)
APPLICATION
A double skinned flexible flue liner suitable for relining within a masonry chimney. Flue liner is suitable for use with burning gas, oil, coal, coke, cured dry logs, cured dry peat, smokeless fuels.
CONSTRUCTION
The flue liner has a smooth inner liner made from 904L grade stainless steel and is 0.12mm thick. The flue liner has a convoluted outer skin made from 904L stainless steel and is 0.12mm thick. The Flue Liner is constructed from a single strip of steel which is bent at 180 degrees and then the seam is folded in four planes to give a Quattro lock seal.
APPROVAL
Flue Liner is approved and listed by HETAS
INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.


INSTALLATION
Flue Liner should always be fitted from the top.
Make sure the arrows are pointing upwards (gas flow).
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).

Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.


MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.

Monday 24 March 2014

Flue Liner 4 inch Nose Cone
** Nose Cone
 
The nose cone is attached to the leading end of the liner, it helps prevent snagging against the side of the stack during installation. Please note that draw cords are not supplied.

Thursday 20 March 2014

Flue Liner 316L/904L Grade Multifuel (316L/904L Grade)

** Flue Liner 316L/904L Grade Multifuel (316L/904L Grade)

Multi fuel flexible liner made from 904L grade stainless steel on the inner and 316L grade stainless steel on the outer walls, both the smooth inner liner and convoluted outer skin being 0.12mm thick. - 15 year manufacturers warranty with this product.

Wednesday 19 March 2014

Flue Liner 10 inch Rain Cap

** Rain Cap

Provides rain protection at the top of the stack.

APPLICATION
Provides rain protection at the top of the stack.

INSTALLATION
Terminal slides over the top of the liner and can be screwed into place with self tapping screws (not supplied) or alternatively can be cemented in to place at the top of the stack.
 
MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.

Friday 14 March 2014

Flue Liner 316L for Gas and Oil (316L Grade)

** Flue Liner 316L for Gas and Oil (316L Grade)

APPLICATION
A single skin flexible flue liner suitable for relining within a masonry chimney. Suitable for use on appliances fired by gas ( as specified by the fire manufacturer ), and oils up to 28 second, and designed to accommodate temperatures not exceeding 260ËšC.

CONSTRUCTION
The flue liner is manufactured from 316L grade stainless steel and is 0.10mm thick. The flue liner has five convoluteions between each seam. The Flue Liner seam is folded in three planes to give a TRIPLELOCK seal.

APPROVAL
TRIPLELOCK Flue Liner is Kitemarked to BS 715 and has been approved and tested to BS EN 1856:2

DESIGNATION NUMBER
BS EN 1856:2 T250 N1 D V3 L50010 G

INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.


INSTALLATION
Flue Liner should always be fitted from the top.
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone. If necessary cut the flue liner to length, and secure the liner at the top using the clamp plate. Ensure 75mm of the flue liner projects above the clamp plate so that the terminal can be located and secured.
Secure and seal the flue liner to a register plate, which closes off the appliance recess. Alternatively the end of the flue liner can be sealed into flue pipe or a Flue Gas Collector or Flue Box.
Terminate the flue liner by securley fitting the terminal to the projecting section of flue liner. Apply a suitable cement as a seal and weather proof render.



MAINTENANCE
It is recommended that chimneys serving gas and oil appliances be swept and maintained as frequently as necessary but at least once a year.

Monday 10 March 2014

Flue-Liner Installation Kit 5 - 5 inch

** Installation Kit 5 5 inch

Installation Pack No. 5, ALL YOU NEED IN ONE BOX FOR USE WITH 125mm diameter multifuel flex.
 
APPLICATION
Use this pack when you want to remove the existing chimney pot, or the chimney does not have a pot.
PACK CONTAINS
1 x Top Plate - diam125mm
1 x Top Clamp - diam125mm
1 x Top Insert - diam125mm
1 x Nose Cone - diam125mm
1 x Increasing Adaptor to Black Pipe or Single Wall Flue - diam100mm SW to diam125mm Flex
1 x Chimney Notice Plate

1 x Rain Cap - diam125mm

Thursday 6 March 2014

7 inch Flue Liner 904L/904L Grade Multifuel (904L/904L Grade)

** Flue Liner 904L/904L Grade Multifuel (904L/904L Grade)

Multi fuel flexible liner made from 904L grade stainless steel on both the inner and outer walls - 25 year manufacturers warranty with this product

APPLICATION
A double skinned flexible flue liner suitable for relining within a masonry chimney. Flue liner is suitable for use with burning gas, oil, coal, coke, cured dry logs, cured dry peat, smokeless fuels.

CONSTRUCTION
The flue liner has a smooth inner liner made from 904L grade stainless steel and is 0.12mm thick. The flue liner has a convoluted outer skin made from 904L stainless steel and is 0.12mm thick. The Flue Liner is constructed from a single strip of steel which is bent at 180 degrees and then the seam is folded in four planes to give a quattrolock seal.

APPROVAL
Flue Liner is approved and listed by HETAS

WARRANTY

904L Grade Flue Liner is warranted for 25 years (conditions apply)

INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.


INSTALLATION
Flue Liner should always be fitted from the top.
Make sure the arrows are pointing upwards (gas flow).
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.

MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.

Wednesday 5 March 2014

Flue Liner 316L for Gas and Oil (316L Grade) 7 inch

** Flue Liner 316L for Gas and Oil (316L Grade)

Suitable for use on appliances fired by gas ( as specified by the fire manufacturer ), and oils up to 28 second.

APPLICATION
A single skin flexible flue liner suitable for relining within a masonry chimney. Suitable for use on appliances fired by gas ( as specified by the fire manufacturer ), and oils up to 28 second, and designed to accommodate temperatures not exceeding 260°C.

CONSTRUCTION
The flue liner is manufactured from 316L grade stainless steel and is 0.10mm thick. The flue liner has five convolutions between each seam. The Flue Liner seam is folded in three planes to give a TRIPLELOCK seal.

APPROVAL
TRIPLELOCK Flue Liner is kite marked to BS 715 and has been approved and tested to BS EN 1856:2

DESIGNATION NUMBER
BS EN 1856:2 T250 N1 D V3 L50010 G

INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.
 
INSTALLATION
Flue Liner should always be fitted from the top.
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone. If necessary cut the flue liner to length, and secure the liner at the top using the clamp plate. Ensure 75mm of the flue liner projects above the clamp plate so that the terminal can be located and secured.
Secure and seal the flue liner to a register plate, which closes off the appliance recess. Alternatively the end of the flue liner can be sealed into flue pipe or a Flue Gas Collector or Flue Box.
Terminate the flue liner by securley fitting the terminal to the projecting section of flue liner. Apply a suitable cement as a seal and weather proof render.

 


MAINTENANCE
It is recommended that chimneys serving gas and oil appliances be swept and maintained as frequently as necessary but at least once a year.

Friday 28 February 2014

Fireplace Hearth Fence 120x120x120x65cm
Fireplace Hearth Fence 120x120x120x65cm
Aduro offers a three sided child safety screen. 
The robust screen can be placed in front of the oven to secure that small children do not come to close to the flames. 
The design still ensures a good view of the flames.

Measures: Height: 65 cm, Width: 120x120x120 cm
Powder coated black metal.
Coupling M/M Black enamel finish
** Coupling M/M Black enamel finish
APPLICATIONSuitable for pellet appliances with temperatures up to 750 degrees C.
Pellet Stove Pipe should only be used as a connecting pipe between your appliance and Flue Liner / Chimney Stack / Twin Wall Flue System.
Pellet Stove Pipe should NOT be used to pass through ceilings or wall.
CONSTRUCTIONPellet Stove Pipe is a single skin flue system manufactured in zero carbon steel with vitreous enamel coating in a matt black finish.
Suitable for Pellet fuel appliances with temperatures up to 750 degrees C.
INSTALLATIONYou should not install a piece of Black Stove Pipe within 3 times the diameter of the flue from combustible material, e.g. wood, plaster boards, etc.
A 5 inch (125mm) diameter piece of Black Stove Pipe should be 15 inches (375mm) away from combustible materials.
When installing make sure Black Stove Pipe is installed the correct way up - the smaller diameter should always be pointing downward.
This is because all the condensates will stay within the flue system and not pass to the outside of Black Stove Pipe.
Each joint should be coated with a jointing compound (fire cement or high temperature silicone sealant).This makes sure that no condensate can escape and spoil the appearance of the pipe.

Thursday 20 February 2014

6 inch Classic Twinwall 135º Tee Ø 150 - BLACK

** 135º Tee Ø 150 - BLACK

The 135° Tee is used when you need a cleaning access at the base of the chimney. It is the first piece installed on the external wall and allows for ease cleaning of the flue. The 135° Tee is shaped in such away that it does not restrict the flue gases.
This item comes with a 2 FREE Locking Bands.
APPLICATION
For use on solid fuel and gas/oil appliances. eg: woodstoves, gas coal effect fires, oil boiler and any solid fuel appliances.

CONSTRUCTION
Outer skin is made from 304 grade stainless steel and is 0.4mm thick. This is then powder coated in a high temperature Black finish. The Inner skin is made from 316 grade stainless steel and is 0.4mm thick. Insulation is compressed rockwool giving a density of 128kg per cubic metre. All parts are fully welded.
Distance to combustibles is 60mm.

APPROVALS
KC is HETAS Approved and is CE marked

Designation Number is
EN1856-1 T600 N1 D V2 L50040 G60.

INSTALLATION
KC Twin Wall Insulated Chimney parts are secured together by using a Locking Band (supplied).
Make sure that you keep a distance of 60mm from the outside of the flue to any combustible material (wood, plaster board).

Wednesday 19 February 2014

Flue Liner 904L/904L Grade Multifuel (904L/904L Grade)

** Flue Liner 904L/904L Grade Multifuel (904L/904L Grade)

Multi fuel flexible liner made from 904L grade stainless steel on both the inner and outer walls - 25 year manufacturers warranty with this product.
 
APPLICATION
A double skinned flexible flue liner suitable for relining within a masonry chimney. Flue liner is suitable for use with burning gas, oil, coal, coke, cured dry logs, cured dry peat, smokeless fuels.
CONSTRUCTION
The flue liner has a smooth inner liner made from 904L grade stainless steel and is 0.12mm thick. The flue liner has a convoluted outer skin made from 904L stainless steel and is 0.12mm thick. The Flue Liner is constructed from a single strip of steel which is bent at 180 degrees and then the seam is folded in four planes to give a quattrolock seal.
APPROVAL
Flue Liner is approved and listed by HETAS

WARRANTY

904L Grade Flue Liner is warranted for 25 years (conditions apply)
INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using)
2.Sweep your chimney.
3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.


INSTALLATION
Flue Liner should always be fitted from the top.
Make sure the arrows are pointing upwards (gas flow).
Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately).
Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney
Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.
MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.