Thursday 19 July 2012

Register Plate (D) 1250mm x 600mm

Register Plate (D) 1250mm x 600mm
Register Plates are used to seal off the base of the chimney. This Register Plate is 1250mm x 600mm

USE THIS REGISTER PLATE WHEN VERMICULITE IS TO BE USED TO INSULATE THE FLUE.

APPLICATION
Use to seal off the base of the chimney (This Register Plate can be cut on site to fit the base size of your chimney stack). The Register Plate will support vermiculite and stop any debris from within the chimney stack coming down the chimney and hitting your stove.

CONSTRUCTION
The Register Plate and the Supporting Brackets are made from 1.5mm thick galvanised steel. The Register Plate can be sprayed to match the colour of your stove pipe.

INSTALLATION
The four supporting brackets should be cut to the length and width of the base of your chimney stack. Drill a number of holes in the brackets. Now screw them into the brickwork. Cut the Register Plate to the correct size, taking care that the pipe hole lies vertically above the Black Stove Pipe. Drop the Register Plate onto the supporting brackets. Now seal any gaps between the brickwork and the brackets / plate using Fire Cement or High Temperature Sealant. For 150mm diameter installations simply remove the centre cover ring by unscrewing the two retaining screws.

Register Plate (C) 1250mm x 600mm - 2 access holes

Register Plate (C) 1250mm x 600mm - 2 access holes
Register Plates are used to seal off the base of the chimney. This Register Plate is 1250mm x 600mm It has TWO access hole. It is suitable for 125mm and 150mm (5 and 6 inch) Black Stove Pipe.

DO NOT USE THIS REGISTER PLATE IF YOU ARE USING VERMICULITE TO INSULATE YOUR FLUE.

APPLICATION
Use to seal off the base of the chimney (This Register Plate can be cut on site to fit the base size of your chimney stack). The Register Plate will support vermiculite and stop any debris from within the chimney stack coming down the chimney and hitting your stove.

CONSTRUCTION
The Register Plate and the Supporting Brackets are made from 1.5mm thick galvanised steel. The Register Plate can be sprayed to match the colour of your stove pipe. This Register Plate has a special adapter suitable for installations which use either 125mm or 150mm diameter flue pipes.

INSTALLATION
The four supporting brackets should be cut to the length and width of the base of your chimney stack. Drill a number of holes in the brackets. Now screw them into the brickwork. Cut the Register Plate to the correct size, taking care that the pipe hole lies vertically above the Black Stove Pipe. Drop the Register Plate onto the supporting brackets. Now seal any gaps between the brickwork and the brackets / plate using Fire Cement or High Temperature Sealant. For 150mm diameter installations simply remove the centre cover ring by unscrewing the two retaining screws.

MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year. At the same time remove the Register Plates inspection hole cover plate(s) and hoover / sweep any debris that has fallen.

DO NOT REMOVE COVER PLATES IF VERMICULITE HAS BEEN INSTALLED AS ADDED INSULATION.

Register Plate (B) 1000mm x 400mm - 2 access holes

Register Plate (B) 1000mm x 400mm - 2 access holes
Register Plates are used to seal off the base of the chimney. This Register Plate is 1000mm x 400mm It has TWO access hole. It is suitable for 125mm and 150mm (5 and 6 inch) Black Stove Pipe.

DO NOT USE THIS REGISTER PLATE IF YOU ARE USING VERMICULITE TO INSULATE YOUR FLUE.

APPLICATION
Use to seal off the base of the chimney (This Register Plate can be cut on site to fit the base size of your chimney stack). The Register Plate will support vermiculite and stop any debris from within the chimney stack coming down the chimney and hitting your stove.

CONSTRUCTION
The Register Plate and the Supporting Brackets are made from 1.5mm thick galvanised steel. The Register Plate can be sprayed to match the colour of your stove pipe. This Register Plate has a special adapter suitable for installations which use either 125mm or 150mm diameter flue pipes.

INSTALLATION
The four supporting brackets should be cut to the length and width of the base of your chimney stack. Drill a number of holes in the brackets. Now screw them into the brickwork. Cut the Register Plate to the correct size, taking care that the pipe hole lies vertically above the Black Stove Pipe. Drop the Register Plate onto the supporting brackets. Now seal any gaps between the brickwork and the brackets / plate using Fire Cement or High Temperature Sealant. For 150mm diameter installations simply remove the centre cover ring by unscrewing the two retaining screws.

MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year. At the same time remove the Register Plates inspection hole cover plate(s) and hoover / sweep any debris that has fallen. DO NOT REMOVE COVER PLATES IF VERMICULITE HAS BEEN INSTALLED AS ADDED INSULATION.

Register Plate (A) 800mm x 400mm - 1 access hole

Register Plate (A) 800mm x 400mm - 1 access hole
Register Plates are used to seal off the base of the chimney. This Register Plate is 800mm x 400mm It has ONE access hole. It is suitable for 125mm and 150mm (5 and 6 inch) Black Stove Pipe.

DO NOT USE THIS REGISTER PLATE IF YOU ARE USING VERMICULITE TO INSULATE YOUR FLUE.

APPLICATION
Use to seal off the base of the chimney (This Register Plate can be cut on site to fit the base size of your chimney stack). The Register Plate will support vermiculite and stop any debris from within the chimney stack coming down the chimney and hitting your stove.

CONSTRUCTION
The Register Plate and the Supporting Brackets are made from 1.5mm thick galvanised steel. The Register Plate can be sprayed to match the colour of your stove pipe. This Register Plate has a special adapter suitable for installations which use either 125mm or 150mm diameter flue pipes.

INSTALLATION
The four supporting brackets should be cut to the length and width of the base of your chimney stack. Drill a number of holes in the brackets. Now screw them into the brickwork. Cut the Register Plate to the correct size, taking care that the pipe hole lies vertically above the Black Stove Pipe. Drop the Register Plate onto the supporting brackets. Now seal any gaps between the brickwork and the brackets / plate using Fire Cement or High Temperature Sealant. For 150mm diameter installations simply remove the centre cover ring by unscrewing the two retaining screws.

MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year. At the same time remove the Register Plates inspection hole cover plate(s) and hoover / sweep any debris that has fallen.

DO NOT REMOVE COVER PLATES IF VERMICULITE HAS BEEN INSTALLED AS ADDED INSULATION.

Increasing Flue Adapter 125 Rigid to 175 Flex

Increasing Flue Adapter 125 Rigid to 175 Flex
A metal connector which connects the flexible chimney liner (one diameter size bigger - ie. 7 inch (175mm)) to single wall pipe at the base of the stack. 

APPLICATION
Connects 180mm (7 inch) Flue Liner to 125mm (5 inch) Black Pipe / Vitreous Enamel / 1mm Stainless / Single Wall flue at the bottom of the chimney stack.

CONSTRUCTION
Made from 316 grade stainless steel, it has integral drain hole to let the condensates flow back into the flue.

INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using) 2.Sweep your chimney. 3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.

INSTALLATION
Flue Liner should always be fitted from the top. Make sure the arrows are pointing upwards (gas flow). Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately). Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.

MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.

Increasing Flue Adapter 125 Rigid to 150 Flex

Increasing Flue Adapter 125 Rigid to 150 Flex
A metal connector which connects the flexible chimney liner (one diameter size bigger - ie. 6 inch (150mm)) to single wall pipe at the base of the stack.
APPLICATION
Connects 150mm (6 inch) Flue Liner to 125mm (5 inch) Black Pipe / Vitreous Enamel / 1mm Stainless / Single Wall flue at the bottom of the chimney stack. HETAS recommend that if you are burning wood then you should increase the size of the flue liner by 25mm from the appliances spigot size. This is due to the amount of condensates that can be produced from burning unseasoned wood.

CONSTRUCTION
Made from 316 grade stainless steel, it has integral drain hole to let the condensates flow back into the flue.

INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using) 2.Sweep your chimney. 3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.

INSTALLATION
Flue Liner should always be fitted from the top. Make sure the arrows are pointing upwards (gas flow). Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately). Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.

MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.

Flue Adapter 125 Rigid to 125 Flex

Flue Adapter 125 Rigid to 125 Flex
A metal connector which connects the flexible chimney liner to single wall pipe at the base of the stack.

APPLICATION
Connects 125mm (5 inch) Flue Liner to 125mm (5 inch) Black Pipe / Vitreous Enamel / 1mm Stainless / Single Wall flue at the bottom of the chimney stack.

CONSTRUCTION
Made from 316 grade stainless steel, it has integral drain hole to let the condensates flow back into the flue.

INSTALLATION - CHECK LIST
1.Make sure the liner will go down the chimney (this can be done by pulling down a small section of the diameter liner you will be using) 2.Sweep your chimney. 3.Check you pot is in good condition, if you are NOT using a suspended cowl then remove the pot from the stack.

INSTALLATION
Flue Liner should always be fitted from the top. Make sure the arrows are pointing upwards (gas flow). Secure a piece of string (at least the same length as the Flue Liner to the Nose Cone (order separately). Now attach the Nose Cone onto the end of the Flue Liner, again making sure the arrows on the Flue Liner are pointing away from the Nose Cone in a upward direction so when the liner is installed the arrows will be pointing to the top of the chimney Pull the liner down the chimney using the string and at the same time have someone at the top of the chimney feeding the Flue Liner down, once the Flue Liner is fitted remove the Nose Cone.

MAINTENANCE
It is recommended that chimneys serving solid fuel appliances be swept and maintained as frequently as necessary but at least once a year.

Installation Kit 8 - 125mm (5 inch)

Installation Kit 8 - 125mm (5 inch)

Installation Pack No. 8, ALL YOU NEED IN ONE BOX FOR USE WITH 125mm diameter multifuel flex

APPLICATION

Use this pack when you DO NOT want to remove the existing chimney pot.

PACK CONTAINS
1 x Terracotta Pot Hanging Cowl with Mesh - Ø125mm 1 x Nose Cone - Ø125mm 1 x Increasing Adapter to Black Pipe or Single Wall Flue - Ø100mm SW to Ø125mm Flex 1 x Chimney Notice Plate

Installation Kit 7 - 125mm (5 inch)

Installation Kit 7 - 125mm (5 inch)

Installation Pack No. 7, ALL YOU NEED IN ONE BOX FOR USE WITH 125mm diameter multifuel flex
APPLICATION
Use this pack when you DO NOT want to remove the existing chimney pot.

PACK CONTAINS
1 x Terracotta Pot Hanging Cowl with Mesh - Ø125mm 1 x Nose Cone - Ø125mm 1 x Adapter to Black Pipe or Single Wall Flue - Ø125mm 1 x Chimney Notice Plate

Installation Kit 6 - 125mm (5 inch)

Installation Kit 6 - 125mm (5 inch)
Installation Pack No. 6, ALL YOU NEED IN ONE BOX FOR USE WITH 125mm diameter multifuel flex

APPLICATION
Use this pack when you DO NOT want to remove the existing chimney pot.

PACK CONTAINS
1 x Stainless Steel Pot Hanging Cowl with Mesh - Ø125mm 1 x Nose Cone - Ø125mm 1 x Increasing Adapter to Black Pipe or Single Wall Flue - Ø100mm SW to Ø125mm Flex 1 x Chimney Notice Plate

Installation Kit 5 - 125mm (5 inch)

Installation Kit 5 - 125mm (5 inch)

Installation Pack No. 5, ALL YOU NEED IN ONE BOX FOR USE WITH 125mm diameter multifuel flex

APPLICATION
Use this pack when you want to remove the existing chimney pot, or the chimney does not have a pot.

PACK CONTAINS
1 x Top Plate - Ø125mm 1 x Top Clamp - Ø125mm 1 x Top Insert - Ø125mm 1 x Nose Cone - Ø125mm 1 x Increasing Adapter to Black Pipe or Single Wall Flue - Ø100mm SW to Ø125mm Flex 1 x Chimney Notice Plate 1 x Rain Cap - Ø125mm

Installation Kit 4 125mm (5 inch)

Installation Kit 4 125mm (5 inch)
Installation Pack No. 4, ALL YOU NEED IN ONE BOX FOR USE WITH 125mm diameter multifuel flex

APPLICATION
Use this pack when you want to remove the existing chimney pot - and then replace it when the flue liner is installed. You will probably need to install a cowl or terminal for your chimney to offer some weather and bird protection

PACK CONTAINS
1x Top Plate - Ø125mm 1 x Top Clamp - Ø125mm 1 x Top Insert - Ø125mm 1 x Nose Cone - Ø125mm 1 x Increasing Adapter to Black Pipe or Single Wall Flue - Ø100mm SW to Ø125mm Flex 1 x Chimney Notice Plate